Sanyo VCC-N4598PC Security Camera User Manual


 
6
Viewing Live Images on a Monitor (Basic Connections)
All the power supplied to the system should be turned off when you connect devices.
POWER VIDEO OUT
LAN
LINK
CLASS 2 WIRING
GND
AC24V
--
DC12V
--
ALARM OUT
ALARM IN
COM
Alarm Signal Output
Alarm Signal Input
Monitor Connection
Using different cables from those specified here may
attenuate the video and/or sync signals and interfere with
correct transmission.
~
~
GND
+
Power Supply Connection
To prevent a fire hazard use any UL listed
wire rated VW-1.
Check that +/– polarity is correct.
AC 24V
DC 12V
(Non-PoE power supply)
1
1 Thicker than 18 AWG
If a lamp is connected to this cable, it will
light up when an alarm signal is received
or when the built-in motion sensor detects
movement.
External
peripheral
equipment
Alarm
input
signal
Thicker than 24 AWG, 600 m / 656 yds. max.
Thicker than RG-6U (5C-2V): 500 m / 547 yds. max.
(COM)
(ALARM IN)
(COM)
(ALARM OUT)
11
11
• To use the ALARM OUT setting, you must
make the appropriate ALARM OUT
settings for CAMERA SETTINGS in the
network settings.
• To use the ALARM IN setting, you must
make the appropriate ALARM IN settings
for CAMERA SETTINGS in the network
settings.