Sekonic L-758 Digital Camera User Manual


 
-33-
2. Turn any secondary light source off. Point the
Lumisphere toward the main light source, from the
position of the subject and take a measurement. Press
the Memory button and store the value in memory.
3. Press the AVE./ EV button and display the “A”mark
on the LCD indicating a standard value.
4. Turn the main lighting off. Now, point the Lumisphere
toward the secondary light source. While pressing and
holding the Measuring button , the indicated
difference between the main and secondary light
source is displayed in EV. At the same time, the
standard value and a new measured value are
displayed on the analog scale.
5. The Standard value can be cleared by pressing the Memory clear button @3 , or AVE./ EV
button.
Reference:
To determine exposure after adjusting lights, turn both main and secondary light sources
on, raise the Lumisphere to the mark position, then take a reading with the Lumisphere
aimed in the direction of camera's lens axis in incident light.
This function can also be used for reflected light.
You can select aperture scale or latitude scale by holding Mode button and pressing
AVE. / EV.
2 : 1
3 : 1
4 : 1
8 : 1
16 : 1
EV difference of EV value
Contrast ratio
1
1.5
2
3
4
6. Advanced Functions
Memorized
f stop value
Set shutter speed
Contrast in
EV
f stop value
being measured
Indicator of reading
Memory button