Sony EX780SP Camcorder User Manual


 
12
Basic Functions
3
1
.
7
3
°
2
1
.
0
9
°
1
.
5
3
°
13.18
11.24
9.93
L=0.3
R41.27
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.
Spectral Sensitivity
Characteristics
Vibrational
Specifications
Test method (Random vibration)
Fix the camera at the four fixation points of the base
using M2 screws.
Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
The camera vibrational specification is to have no
malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz 4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz -36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes
Wave Length [nm]
Mg
G
Cy
Ye
400
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
450 500 550 600 650 700
Relative Response