Sony FCB-EX48C Camera Accessories User Manual


 
30
Basic Functions
Spectral Sensitivity
Characteristics
Vibration
Specifications
Test Method (Random vibration)
• Fix the camera at the four fixation points of the base
using M2 screws.
• Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
• The camera vibration specification is to have no
malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz 4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz –36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes
1
Ye
Cy G
Mg
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400 500 600 700 800 900 1000
Wave Length [nm]
Relative Response
31.2˚
11.13
15.9˚
14.18
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.