Tandberg Video on Frame Relay
D11624 rev.01 11
• 4 configuration entries, each of which contains TX and RX DLCI settings, User
Clock Speed, Packet Length, and AVB
• LMI type control selection & parameter entry (ITU Annex A, ANSI Annex D, Frame
Relay Forum, or Off)
• Master, Slave, or Auto-assign settings for Enhanced Buffer Management
• Local/Remote loopback facilities
Memory:
4 configuration entries are maintained within the memory of the VFX-250S. These can
be updated from the much larger configuration library in the Windows-based
configuration software. All configuration parameters are stored in non-volatile memory.
7.6 Mechanical/Environmental
Overall Size:
H: 4.6 cm (1.8")
W: 21.4 cm (8.4")
D: 20.9 cm (8.3")
Temperature:
Operating: 0° to +50°C
Non-operating:-20° to +70°C
Humidity:
10 to 90 % non-condensing
Altitude:
3,050 M (10,000 ft)
7.7 Power Supply
AC Input:
100 to 250 VAC (50 - 60 Hz), 15 W maximum
Type:
Universal Desktop with IEC 320 AC input connector (can be supplied with a variety of
North American/International power cords)
Size:
H: 3.8 cm (1.5")
W: 6.6 cm (2.6")
D: 10.2 cm (4.0")