Toshiba CS8560D Security Camera User Manual


 
(b) Non-reset mode (Under external sync --- Single VD IN)
After TRIG IN and exposure, the camera goes into standby until next ext. VD IN.
1/60s Non-interlace
*Don’t provide ext. VD IN during exposure.
** After automatic return, fix ext. VD IN at Hi.
1/120s 2:1 Interlace
Video output field (ODD/EVEN) is determined by ext. VD falling edge and ext. HD
phase.
*Don’t provide ext. VD IN during exposure.
** After automatic return, fix ext. VD IN at Hi.
In sync with ext.VD during standby
(No video output)
TRIG IN
(Positive)
EXT VD
CCD Exposure
VIDEO OUT
WEN OUT
(Standard)
WEN OUT
[Option]
TRIG IN not acceptable for
1V after mode chenge
Automatically returns to normal shutter
if fixed H level (after approx. 1/6s)
Exposure time
(E-shutter speed or
pulse width)
Outputs video at the next VD
timing after exposure
Normal shutter
Random trigger shutter Normal shutter
Definite
ODD EVEN
EVEN
ODD EVEN ODD
ODD
phase
ODD EVEN EVEN ODD
EVEN
phase
ODD
EVEN
image
ODD
image
ODD
phase
TRIG IN
(Positive)
EXT VD
CCD Exposure
VIDEO OUT
WEN OUT
(Standard)
WEN OUT
[Option]
TRIG IN not acceptable for
1V after mode chenge
Exposure time
(E-shutter speed or
pulse width)
In sync with ext.VD during standby
(No video output)
Outputs video at the next VD
timing after exposure
Automatically returns to normal shutter
if fixed H level (after approx. 1/6s)
Definite
Normal shutter
Random trigger shutterNormal shutter
D4130891A