D4153660A
10
9. Troubleshooting
If any trouble occurs in use, check the following first. If the trouble persists, contact your distributor or our sales
representatives.
* When user confirms the troubles, please confirms the troubles on the condition that user connected the camera
system on the smallest composition and set 1500 byte / packet to the GVSP_SIZE (SCPSx) register for
making cause of trouble clear. About the connection of the smallest constitution, please refer to 6.Connection.
Phenomena Check item
Cannot turn on power - Check the connection of the Camera cable.
- Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.
Shooting image is not displayed - Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the ACT LED(LED1) is lighting or blinking.
- Check that the camera register settings are correct.
- Check that the lens aperture is not closed.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.
Frame drop occurs on shooting
image
- If some boards are installed in the PCI slots, remove the other
boards.
Shooting image remains still - Check that the camera is not in the random trigger mode.
- Check that the ACT LED(LED1) is lighting or blinking.
Cannot control camera from PC - Check that the LINK LED(LED2) is lighting.
If the LINK LED(LED2) is not lighting, check the connection of
the LAN cable.
- Check that the Gigabit Ethernet interface board is installed and set
up correctly.