Toshiba IK - HD1C Security Camera User Manual


 
28
6
SYNC
When an external sync signal is input, the display changes from INT (internal sync) to EXT.(external sync)
automatically.
INT EXT
6
1
INT screen
-- 6 SYNC -- <FILE A>
MODE INT
6
2
Changing EXT. setting
Sync system display
-- 6 SYNC -- <FILE A>
H PHASE -1024 to 1023
MODE EXT
H PHASE 0
(a) Adjusting horizontal phase
Move the “” to H PHASE by pushing [MENU UP], [MENU DOWN] buttons.
Select the desired value of horizontal phase by pushing [DATA UP], [DATA DOWN] buttons.
DATA UP
1024 0 1023
DATA DOWN
* If the phase difference is big, press [DATA UP]/[DATA DOWN] button for a while.
It makes the setting shift by tens place.
Move up and down
by pushing
MENU UP,DOWN
Select the desired
value by pushing
DATA UP,DOWN