Unibrain 702 Digital Camera User Manual


 
Unibrain Fire-i 501/511/601/701/702/810 Operation Manual Page 36
3.10.3. Trigger & Strobe delay
For Fire-i 501/511/601, the strobe signal starting point is almost the same as the exposure starting point.
For Fire-i 701/702/810, the strobe signal starting point is almost the same as the external trigger starting point.
Fire-i 501/511/601
Fire-i 701/702/810
3.10.4. Trigger Mode 0
Camera starts integration of the incoming light from external trigger input falling edge. Integration time is described in
the "Shutter" register. No parameter is needed. A Trigger delay is applied to mode 0 for H/W trigger. The Trigger in
mode 0 is supported by both H/W trigger and S/W trigger.