Unibrain Fire-i 501/511/601/701/702/810 Operation Manual Page 45
3.14. Optical Filter Control
Optical Filter control allow user to change the optical filter of the camera lens function. You can change the Bayer
patterns by moving the starting position which to output pixel data by one position up, down, right or left. (Only for
color models)
Inquiry Register
Address Name Field Bit Description
58Ch OPTICAL_FILTER_INQ Presence_Inq [0] Presence of this feature
Abs_Control_In
q
[1] Capability of control with absolute value
- [2] Reserved
One_Push_Inq [3] One push auto mode (Controlled automatically
by camera only once)
ReadOut_Inq [4] Capability of reading the value of this feature
On/OFF_Inq [5] Capability of switching this feature ON and
OFF
Auto_Inq [6] Auto Mode (Controlled automatically by
camera)
Manual_Inq [7] Manual Mode (Controlled by user)
Min_Value [8..19] Minimum value for this feature control
Max_Value [20..31] Maximum value for this feature control
Status Control Register
Address Name Field Bit Description
88Ch OPTICAL_FILTER Presence_Inq [0] Presence of this feature 0:N/A 1:Available
Abs_Control [1] Absolute value control
0: Control with value in Value field
1: Control with value in Absolute value
CSR if this bit =1, value in Value filed is
ignored
- [2..5] Reserved
On/OFF [6] Write : ON or OFF this feature
Read : read a status, 0: OFF, 1:ON
If this bit=0, other fields will be read only.
- [7..19] Reserved
Value [20..31] Minimum value for this feature control