Unibrain 830 Digital Camera User Manual


 
Unibrain Fire-i 530/630/830 Operation Manual Page 28
3.9.4. Trigger Mode 0
The Camera starts integration of the incoming light from the external trigger input falling edge. The Integration
time is described in the "Shutter" register. No parameter is needed.
3.9.5. Trigger Mode 1
The camera starts the integration of the incoming light from the external trigger input falling edge. The integration
time is equal to the low state time of the external trigger input. No parameter is needed.
3.9.6. Trigger Mode 2
The camera starts the integration of incoming light from the first external trigger input falling edge. At the N-th
(parameter) external trigger input falling edge, the integration will be stopped. A parameter is required and shall be
two or more. (N >= 2).