Vivotek FE8181V Security Camera User Manual


 
VIVOTEK
User's Manual - 207
version string[40] <blank> 6/6 Version of the module.
license string[40] <blank> 6/6 Indicate the license
status of the module.
path string[40] <blank> 6/6 Record the storage path
of the module.
initscr string[40] <blank> 6/6 The script that will
handle operation
commands from the
system.
status string[40] <blank> 6/6 Indicate the running
status of the module.
7.41 Fisheye local dewarp setting
Group: fisheyedewarp_c<n>, where n = channel index from 0 ~ "capability_nvideoin"-1
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
panspeed -5 ~ 5
<intege
r>
0 1/4 Pan speed of regional view
tiltspeed -5 ~ 5
<intege
r>
0 1/4 Tilt speed of regional view
zoomspeed -5 ~ 5
<intege
r>
0 1/4 Zoom speed of regional
s<0~(m-2)>_pano
rama_panstart
0~359
<intege
r>
0 1/4 Initial pan position of panorama
view.
(only available for 1P and 2P
mode at ceiling or floor mount)
s<0~(m-2)>_regio
n_pan
-90~35
9
<intege
r>
315 1/4 Pan home angle of regional
view
Pan range of ceiling/floor
mount is [0~359].
Pan range of wall mount is
[-90~90].
s<0~(m-2)>_regio
n_tilt
-90~90
<intege
r>
40 1/4 Tilt home angle of regional view
Tilt range of ceiling/floor mount
is [0~90].
Tilt range of wall mount is