- 89 -
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
name string[40] 6/6 The identification of this entry
enable 0, 1 6/6 To enable or disable this event.
priority 0, 1, 2 6/6 Indicate the priority of this event.
“0” indicates low priority.
“1” indicates normal priority.
“2” indicates high priority.
delay 1~999 6/6 Delay seconds before detect next
event.
trigger boot,
di,
motion,
seq,
6/6 Indicate the trigger condition.
“boot” indicates system boot.
“di” indicates digital input.
“motion”
indicates video motion
detection.
“seq” indicates periodic condition.
di <integer> 6/6 Indicate which di detected.
T
his field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 6/6 Indicate which
motion detection
windows detected.
T
his field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
inter 1~999 6/6 Interval of period snapshot in minute.
T
his field is used when trigger
condition is “seq”.