- 52 -
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
General format of command URL
Every configuration can be set through URL with the POST method by the
Administrator only.
<general format>
URL[?[name=value][&name=value]……]
<method>
POST
<authorized user>
root
System configuration URL
URL: /setup/system.cgi
NAME VALUE DESCRIPTION
host
<text string shorter than 15
characters>
system name
yes turn off front LED ledoff
no turn off front LED
keep keep date and time unchanged
auto use NTP server to synchronize
method
manu directly adjust date and time
date <yyyy/mm/dd>
year, month and date separated by
slash
time <hh:mm:ss>
hour, minute and second separated
by colon
ntp <domain name or IP address>
NTP server
zone -12 ~ 12 time zone, 8 means GMT +8:00
one hour Synchronize with NTP hourly
one day Synchronize with NTP daily
one week Synchronize with NTP weekly
updateInterval
One month Synchronize with NTP monthly