16
(
*
1
)
For UL version only
(
*
2
)
90kW and over
-FE
(
CE
)
Code
Name
Default Setting
-FU2
(
UL
)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
C011
C012
C013
C014
C015
C019
C027
C028
C029
C031
C032
C036
C040
C041
C042
C043
C044
C061
C070
C071
C072
C073
C074
C075
C078
C081
C082
C083
C085
C086
C087
C088
C091
C101
C102
C103
C121
C122
C123
H003
H203
H004
H204
H006
H206
P001
P002
P031
P044
P045
P046
P047
P048
P049
U001
I
U012
C Group: Intelligent Terminal Functions
H Group: Motor Constants Functions
P Group: Expansion Card Functions
U Group: User-selectable Menu Functions
Intelligent
Input
Terminal
Setting
Intelligent
Input
Terminal
State
Setting
Intelligent
Output
Terminal
State and
Output
Level
setting
Serial
Communi-
cation
Analog
Meter
Setting
Terminal (1) active state
Terminal (2) active state
Terminal (3) active state
Terminal (4) active state
Terminal (5) active state
Terminal FW active state
FM signal selection
AM signal selection
AMI signal selection
Terminal (11) active state
Terminal (12) active state
Alarm relay terminal active state
Overload signal output mode
Overload level setting
Arrival frequency setting for acceleration
Arrival frequency setting for deceleration
PID deviation level setting
Electronic thermal warning level setting
Data command method
Communication speed selection
Node allocation
Communication data length selection
Communication parity selection
Communication stop bit selection
Communication wait time
O input span calibration
OI input span calibration
O2 input span calibration
Thermistor input tuning
AM terminal offset tuning
AMI terminal meter tuning
AMI terminal offset tuning
Debug mode enable
UP/DOWN memory mode selection
Reset mode selection
Restart frequency after reset
O input zero calibration
OI input zero calibration
O2 input zero calibration
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(During accel./decel) / 01(At constant speed)
0.00*rated current-2.00*rated current
0.00
-
99.99/100.0
-
400.0Hz
0.00
-
99.99/100.0
-
400.0Hz
0.0
-
100.0%
0.
-
100.%
02(Operator) / 03(RS485) / 04 (Expansion card 1) / 05(Expansion card 2)
03(2400bps) / 04(4800bps) / 05(9600bps) / 06(19200bps)
1.-32.
7(7-bit) / 8(8-bit)
00(No parity) / 01(Even) / 02(Odd)
1(1-bit) / 2(2-bit)
0.
-
1000.msec.
0.
-
9999./1000
-
6553(10,000
-
65,530)
0.
-
9999./1000
-
6553(10,000
-
65,530)
0.
-
9999./1000
-
6553(10,000
-
65,530)
0.0
-
1000.
0.0
-
10.0V
0.
-
255.
0.
-
20.0mA
00(No display) / 01(Display)
00(Clear previous frequency) / 01(Keep previous frequency)
00(Restart at 0Hz) / 01(Resume operation after frequency matching)
0.
-
9999./1000
-
6553(10,000
-
65,530)
0.
-
9999./1000
-
6553(10,000
-
65,530)
0.
-
9999./1000
-
6553(10,000
-
65,530)
00
00
00
00
00
00
00
00
00
00
01
01
Rated current
0.0
0.0
3.0
80
02
04
1.
7
00
1
0.0
Factory set
Factory set
Factory set
105
0.0
80
Factory set
00
00
00
00
Factory set
Factory set
Factory set
Intelligent
Output
Terminal
Setting
01(RV:Reverse) / 02(CF1:Multipeed(1)) / 03(CF2:Multispeed(2)) / 04(CF3:Multi-
speed(3)) / 05(CF4:Multispeed(4)) / 06(JG:Jogging) / 07(DB:External DC braking) /
08(SET:Second motor constants setting) / 09(2CH:Second accel./decel.) /
11(FRS:Free-run stop) / 12(EXT:External trip) / 13(USP:Unattended start protection) /
14(CS:Change to/from commercial power supply) / 15(SFT:Software lock) /
16(AT:Analog input selection) /18(RS:Reset) / 20(STA:3-wire start) / 21(STP:3-wire
hold) / 22(F/R:3-wire fwd./rev.) / 23(PID:PID On/Off) / 24(PIDC:PID reset) /
27(UP:Remote-controlled accel.) / 28(DWN:Remote-controlled decel.) /
29(UDC:Remote-controlled data clearing) / 31(OPE:Operator control) / 32(SF1:Multi-
speed bit command(1) / 33(SF2:Multispeed bit command(2) / 34(SF3:Multispeed bit
command(3) / 35(SF4:Multispeed bit command(4) / 36(SF5:Multispeed bit com-
mand(5) / 37(SF6:Multispeed bit command(6) / 38(SF7:Multispeed bit command(7) /
39(OLR:Overload limit change)/ 49(ROK: RUN permissive)
(
*
1)
/ 255(NO:Not selected)
00(RUN:Run signal) / 01(FA1:Frequency arrival signal (at the set frequen-
cy))/ 02(FA2:Frequency arrival signal (at or above the set frequency)) /
03(OL:Overload advance notice signal) / 04(OD:Output deviation for PID
control) / 05(AL:Alarm signal) / 06(FA3:Frequency arrival signal (only at the set
frequency)) / 08(IP:Instantaneous power failure signal) / 09(UV:Under-voltage
signal)/ 11(RNT:RUN time over) / 12(ONT:Power-on time over) /
13(THM:Thermal alarm) / 27(RMD: Operator RUN command signal)
(
*
1)
User selected functions
Motor capacity
Motor capacity for second motor
Motor poles setting
Motor poles setting for second motor
Motor stabilization constant
Motor stabilization constant for second motor
Terminal (5) function
Terminal (3) function
Operation mode on Expansion card 1 error
Operation mode on Expansion card 2 error
Accel/deccel time input selection
DeviceNet comm watchdog timer
Inverter action on DeviceNet comm error
DeviceNet polled I/O:Output instance number
DeviceNet polled I/O:Input instance number
Input action on DeviceNet idle mode
Motor poles setting for RPM
00
01
00
Others
00(Output frequency) / 01(Output current) / 03(Digital output frequency-only at
C027) / 04(Output voltage) / 05(Power) / 06(Thermal load ratio) / 07(LAD fre-
quency)
00(Cancel trip state when reset signal turns ON) / 01(Cancel trip state when
reset signal turns OFF) / 02(Cancel trip state when reset signal turns ON(En-
able during trip state))
Terminal (2) function
C005
C003
C002
C001
C021
C022
Terminal (11) function
Terminal (12) function
Terminal (1) function
Terminal (4) function
18
00
00
01
00
00
00
00
00
00
00
01
01
Rated current
0.0
0.0
3.0
80
02
04
1.
7
00
1
0.0
Factory set
Factory set
Factory set
105
0.0
80
Factory set
00
00
00
00
Factory set
Factory set
Factory set
00
01
00
18
1616
1303
02
02
0.20
-
75.0(kW) {
-
160(kW)}
(
*
2)
0.20
-
75.0(kW) {
-
160(kW)}
(
*
2)
2/4/6/8
2/4/6/8
0.
-
255.
0.
-
255.
00(Trip) / 01(Continuous operation)
00(Trip) / 01(Continuous operation)
00(operation)/01(option1)/02(option2)
0.00-99.99s
00(trip)/01(trip after deceleration stop)/02(invalid)/03(free-run)/04(deceleration stop)
20,21,100
70,71,101
00(trip)/01(trip after deceleration stop)/02(invalid)/03(free-run)/04(deceleration stop)
0-38(even only)
00(Output freq.forced to 0Hz; 500ms wait to recover)/01(Output forced 0Hz; no wait to
recover)/02(Output freq.forced to max.freq.A004)/03(Output ferq.forced to A020/A220)
no / d001-P002
C004
Factory set
Factory set
4
4
100.
100.
Factory set
Factory set
4
4
100.
100.
00
00
00
1.00
01
21
71
01
0
00
00
00
00
1.00
01
21
71
01
0
00
no no
= Allowed
= Not permitted
[ ]
01 01
C026 Alarm relay terminal function 05 05
P050
Output frequency on analog reference signal loss