INSTALLATION
-14-
When connecting the Control Module to a non-Lincoln power
source, determine which type of output contactor your power
source has. If the switch is not in the correct position, remove
the single screw securing the lockout bar and remove. Slide the
switch to the correct position and reinstall lockout bar on other side
using screw already in place there. Replace first screw in original
location.
Connection to 487-25 Spool Gun
Connect the electrode cable, gas line, and control cable of the
spool gun to their respective connectors on the front of the
Control Module.
Connection to 469-25 Spool Gun*
1. Connect K518 adapter to spool gun control
cable.
2. Connect the electrode cable, gas line, and control cable of
the spool gun to their respective connectors on the front of
the Control Module.
*Requires K518 adapter (ordered separately)
CAUTION: Be sure that mode switch is in correct position
before attempting to operate control module. Incorrect
switch position could result in damage to the control
module and/or power source. Cunsult your power source
instruction manual to see what type of output contactor
circuit it has. Be sure to reinstall lockout bar if switch
position is altered.
Work Lead Connection
Connect the work lead to the negative (-) polarity output
stud or connector on the power source. Make sure the
lead is of sufficient length and gauge for your setup per
standard welding practice.