B-4
OPERATION
B-4
7A. ADVANCED PROCESS PANEL
(See Figure 2)
To program Welding modes. Select knob is used to
Scroll through all Welding modes. The Memory button
is used to store and access Welding modes into loca-
tions M1 thru M8.
Modes:
In addition to the 5 welding modes described in SEC-
TION 7, the Advance Process Panel allows you to
select the Following additional modes.
• Constant Power mode
In the Power Mode;
The work point will be in the Volts window. The
Amp window will have CP displayed indicating
Constant Power. Once current starts flowing and
during the 5 second “Hold” feature the displays will
show Volts and Amps respectively.
• Gouge
Air Carbon Arc Cutting (CAC-A) is a physical means
of removing base metal or weld metal by using a
carbon electrode, an electric arc and compressed
air.
V350-PRO
• Pulsed Modes
In Pulse Modes;
The work point will be in the Amps window and
should be set close to the wire feed speed of the
wire feeder in inches per minute. The Volts window
will have SPd displayed indicating Wire Feed
Speed. Once current starts flowing and during the 5
second “Hold” feature the displays will show amps
and volts.
Pulse Mode features that are displayed while
selecting a Welding pulse mode are listed below;
Steel - .030, .035, .045, .052 – Argon Blends
Stainless Steel - .030, .035, .045 – Argon Blends &
Helium/Argon Blends
Aluminum - .035, 3/64, 1/16 – 4043 & 5356
Metal Core - .045, .052 – Argon Blends
Nickel - .035, .045 – Argon/Helium blends
MEMOR
MEMORY
MEMORY BUTTON
(M1 THRU M8)
OUTPUT KNOB
SELECT BUTTON
(HOT START OR ARC CONTR
OL)
ADJUST KNOB
(0 THRU 10-HOT START)
(-10 THRU 0 AND
0 THR
U +10-ARC CONTR
U +10-ARC CONTROL)
SELECT KNOB
(SCOLLS
WELDING PR
SELECT
ADJUST
SELECT
7A
WELD
TERMINALS
OUTPUT
CONTR
OL
SELECT
SELECT
MPS
OL
FIGURE 2