A-5
INSTALLATION
SQUARE WAVE TIG 175 PRO
A-5
these steps in reverse.
REMOTE CONTROL CONNECTION
A remote control receptacle is provided on the case
front of the welder for connecting a remote control to
to the machine. A Foot Amptrol
tm
, foot activated remote
control, is included with the SQUARE WAVE TIG 175
PRO. Refer to the Optional Accessories section of this
manual for other available remote controls.
CONNECTIONS FOR STICK (SMAW)
WELDING
STICK ELECTRODE CABLE AND WORK CABLE
CONNECTION
Refer to Included Equipment in the Operation Section
of this manual for STICK welding equipment which is
included with the SQUARE WAVE TIG 175 PRO.
An electrode holder with cable is supplied with the
SQUARE WAVE TIG 175 PRO. Turn the Power
Switch “OFF”. Connect the cable quick connect plug
into the Electrode/Gas Output Receptacle and turn it
clockwise until it is tight. The work cable and work
clamp are factory connected.