logo

MACHINE LOADED TO 180 AMPS AT
26VDC.
This is the typical AC output voltage waveform
generated from a properly operating machine.
Note that each vertical division represents 10
volts and that each horizontal division repre-
sents 2 milliseconds in time. The machine
was loaded with a resistance grid bank. The
grid load meters read 180 amps and 26VDC
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (–)
probe to work.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
DC STICK MODE
TROUBLESHOOTING AND REPAIR
F-36 F-36
PRECISION TIG® 225
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
Perform all voltage and waveform checks with high frequency circuit OFF.
Perform High Frequency Disable Procedure.
____________________________________________________________________
0volts
2ms
50
volts