© Titan Tool Inc. All rights reserved. 37
Hydra M™ & Hydra Pro Super™ Outlet Accessories
Outlet Manifold Filter Assembly
ITEM
NO.
PART
NO.
DESCRIPTION QTY
1 920-917 Filter cap assembly 1
2 920-103 Ball, S.S. 1
3 920-004 Screen, lter, 50 mesh 1
4 920-006
Gasket, PTFE (thick)
1
5 920-070
Gasket, PTFE (thin)
1
6 920-927 Body, lter (5000 psi) 1
7 812-003 Nipple, hex 1
8 227-027 Plug, pipe 1
9 227-033 Plug, pipe 1
10 703-137 Swivel tting 1
Part No. 920-050 Filter Service Kit
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
2 920-103 Ball 1
4 920-006
Gasket, PTFE
1
5 920-070
Gasket, PTFE
1
Cleaning
Clean lter regularly. Dirty or clogged lters can greatly reduce
ltering ability and cause a number of system problems including
poor spray patterns, clogged spray tips, etc.
To clean the lter, shutoff system and relieve all system pressure.
See the Pressure Relief Procedure on page 9.
1. Remove lter cap (1).
2. Pull lter element with check ball (3) straight out of the
lter body (6).
3. Thoroughly clean inside lter body (6), lter element with
check ball (3) and lter cap (1) with appropriate solvent.
Use care in handling parts as dirt, debris, scratches or
nicks may prevent O-rings or gaskets from sealing.
The 920 Series Filter Elements lter from the inside out. Be
certain to clean the screen element thoroughly on the inside.
Soak in solvent to loosen hardened paint, etc. or replace.
Specications
Max. Working Pressure 5000 psi (345 bar)
Filter Area 18in
2
(116 cm
2
)
Outlet Ports (1) 1/4” NPT (F) for
bleed valve
(1) 3/8” NPT (F) with
1/4 NPSM (M) hose
connection
(1) 3/8” NPT (F) plug for
additional gun hookup.
Wetted parts
Carbon steel with
electroless nickel
and cadmium plating,
stainless steel, PTFE