A SERVICE OF

logo

26
NOTE: It is not
necessary to overtighten foot valve and cylinder
into pump block. O-Ring seals perform sealing function without
excessive tightening. Full thread engagement is sufficient. The
Foot Valve may be rotated back up to 1/2 turn from full engage-
ment for convenient hose position.
For syphon hose attachment, it is critically important that the
threads of the syphon hose fit snugly into the foot valve with the
hose assembly couplings
PTFE taped and sealed to prevent air
leakage.
107-501 SERVICE KIT, MAJOR, PUMP
ITEM PART
NO. NO. DESCRIPTION QUANTITY
107-051 Service Kit, Pump 1
6 107-029 Displacement Rod 1
11 107-936 Pump Cylinder 1
107-051 SERVICE KIT, MINOR, PUMP
ITEM PART
NO. NO. DESCRIPTION QUANTITY
1 143-019 Retainer Ring 1
3 106-015
O-Ring, PTFE 2
4 106-002 Packing Set, Leather/UHMWPE 2
7 106-116 Sleeve 1
8A 106-002 Packing Set, Leather/UHMWPE 1
9 569-021 Ball, SS 1
12 106-014
O-Ring 1
14 138-340 Ball, SS 1
426-051 Sealant, Loctite 1
753-024 Sealant, Tape,
PTFE 1