NOTE: It is not
necessary to overtighten foot valve and cylinder
into pump block. O-Ring seals perform sealing function without
excessive tightening. Full thread engagement is sufficient. The
Foot Valve may be rotated back up to 1/2 turn from full engage-
ment for convenient hose position.
For syphon hose attachment, it is critically important that the
threads of the syphon hose fit snugly into the foot valve with the
hose assembly couplings PTFE taped and sealed to prevent air
leakage.
107-501 SERVICE KIT, MAJOR, PUMP
ITEM PART
NO. NO. DESCRIPTION QUANTITY
107-051 Service Kit, Pump 1
6 107-029 Displacement Rod 1
11 107-936 Pump Cylinder 1
107-051 SERVICE KIT, MINOR, PUMP
ITEM PART
NO. NO. DESCRIPTION QUANTITY
1 143-019 1
3 106-015 2
4 106-002 2
7 106-116 1
8A 106-002 1
9 569-021 1
12 106-014 1
14 138-340 1
426-051 1
753-024
Retainer Ring
O-Ring, PTFE
Packing Set, Leather/UHMWPE
Sleeve
Packing Set, Leather/UHMWPE
Ball, SS
O-Ring
Ball, SS
Sealant, Loctite
Sealant, Tape, PTFE
1