A SERVICE OF

logo

© Titan Tool Inc. All rights reserved. 33
Commander™ 920 Outlet Manifold Filter Assembly Service Instructions
Cleaning
Clean lter regularly. Dirty or clogged lters can greatly reduce
ltering ability and cause a number of system problems including
poor spray patterns, clogged spray tips, etc.
To clean the lter, shutoff system and relieve all system pressure.
See the Pressure Relief Procedure on page 7.
1. Remove lter cap (1).
2. Pull lter element with check ball (3) straight out of the
lter body (6).
3. Thoroughly clean inside lter body (6), lter element with
check ball (3) and lter cap (1) with appropriate solvent.
Use care in handling parts as dirt, debris, scratches or
nicks may prevent O-rings or gaskets from sealing.
The 920 Series Filter Elements lter from the inside out. Be
certain to clean the screen element thoroughly on the inside.
Soak in solvent to loosen hardened paint, etc. or replace.
Part No. 920-050 Filter Service Kit
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
2 920-103 Ball 1
4 920-006
Gasket, PTFE
1
5 920-070
Gasket, PTFE
1
Specications
Max. Working Pressure 5000 psi
(345 bar)
6000 psi
(413 bar)
Filter Area 18in
2
(116 cm
2
)
Outlet Ports (1) 1/4” NPT (F) for
bleed valve
(1) 3/8” NPT (F) with
1/4 NPSM (M) hose
connection
(1) 3/8” NPT (F) plug for
additional gun hookup.
Wetted parts
Carbon steel with
electroless nickel
and cadmium plating,
stainless steel, PTFE