Sensor Testing
If the sensor is disconnected or short-circuited, the heating system is
turned off. Test your sensor according to the following resistance table:
Error Codes
E0: Internal error. The thermostat must be replaced.
E2: External sensor short-circuited or disconnected.
Sensor
Temp (˚C) Temp (˚F) Value (ohm)
–10 –14 64000
0 32 38000
10 50 23300
20 68 14800
30 86 9700
QuickStat Installation & Operation Manual