American Dynamics ADSDUHOC Security Camera User Manual


 
SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C
INSTALLATION GUIDE - CONTINUATION
6 of 12
Connector Pin Assignments
GREEN CONNECTOR (POWER)
Pin Color Description
1 Black 24Vac
2 Red Common
3 White 24Vac
BLACK CONNECTOR (DATA)
Manchester
Pin Color* Designation
1-4 — Not used.
5 White/Orange Manchester (White)
6 White/Yellow Manchester (Black)
RS-422 / SensorNet
Pin Color* Designation
1 Orange RS-422 Data In High (+)
2 Green RS-422 Data In Low (–)
3 Yellow RS-422 Data Out High (+)
4 Brown RS-422 Data Out Low (–)
5 White/Orange SensorNet (unshielded)
6 White/Yellow SensorNet (unshielded)
*Color based on composite cable.
GREEN CONNECTOR (TWISTED PAIR VIDEO)
Pin Color Designation
1 + (video high)
2 – (video ground)
GRAY CONNECTOR (RELAY ALARM OUTPUTS)
Pin Color Description
1 Blue Normally Closed*
2 Purple Common*
3 Gray Normally Open*
4 Wht/Red Alarm Return
5 Wht/Blk Alarm input 1 (3.5mA sink)
*Relay contact not to exceed 1A @ 30Vdc or
0.3A @ 125Vac.
BLUE CONNECTOR (ALARM INPUT)*
Pin Color Designation
1 Wht/Blue Alarm input 2
2 Wht/Brn Alarm input 3
3 Wht/Purple Alarm input 4
4 Wht/Red Alarm Return
* 0101-0115-0X non-vandal resistant housing,
0101-0116-0X vandal-resistant housing.
Cable Requirements
Data Cable
The table below shows requirements for SensorNet,
RS-422, and Manchester networks. For more
information about communication protocols and
cable networks, see Communication Protocols and
Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet RS-422 Manchester
Cable type 1
unshielded,
twisted
pair*
2
shielded,
twisted
pair*
1
shielded
twisted
pair**
Wire gauge 22 AWG 22 AWG 18 AWG
Connection Non-
polarized
Polarized Polarized
Max.
devices on
line
32 10 3
* Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables must
be used in indoor ceilings used for environmental air
return (called "other air space" in the National Electrical
Code). Order parts through your distribution network.
Note: If you order cable from an outside source, wire
colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable (non-
plenum) cable is recommended. Plenum-rated cables
must be used in indoor ceilings used for environmental
air return (called "other air space" in the National
Electrical Code). Order
cable directly from Belden by
calling 1-800-235-3361.
Power Cable
The camera dome and housing are to be connected
to a Class 2 LPS, 24Vac, 80VA power source. Do
not exceed the maximum outdoor Class 2 ratings of
30Vac, 100VA.
0.823mm
2
(18AWG)
1.31mm
2
(16AWG)
2.08mm
2
(14AW)G
Low Line Voltage
102/204Vac
60m
(200ft)
100m
(320ft)
160m
(520ft)
Low Line Voltage
90/180Vac
30m
(100ft)
50m
(160ft)
80m
(260ft)