American Dynamics RAS916 Security Camera User Manual


 
SPEEDDOME ULTRA VII CAMERA DOME CONFIGURATION UTILITY 8200-0184-09, REV. A
OPERATOR’S MANUAL SUPPLEMENT
8 of 13
AD2150/AD2350
Supported Protocol RS-422 (1)
Maximum Presets 16 (2) or 60 (3)
Maximum Patterns (4) 3
Quick Set Menu Not supported
Address Range 1-32
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in
the dome, not the converter.
(4) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
AD1650
Supported Protocol RS-422 (1)
Maximum Presets 16 (2) or 60 (3)
Maximum Patterns (4) 3
Quick Set Menu Not supported
Address Range 1-128 (5)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in
the dome, not the converter.
(4) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64
or 99 cameras is reserved as a global broadcast
address.
AD168
Supported Protocol SensorNet (1)
RS-422 (1) or (2)
Maximum Presets
16 (1)(2), 64 (1)(3), or
60 (4)
Maximum Patterns (5) 3
Quick Set Menu Not supported
Address Range SensorNet: 1-180
RS-422: 1-99 (1)(6) or
1-180 (2)(6)
Notes:
(1) Requires the appropriate code control module.
(2) Requires the AD2083-02 series code converter.
(3) Presets information is stored at the converter or
control module, not the dome.
(4) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in
the dome, not the converter.
(5) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
(6) Requires additional equipment to achieve these
numbers. A dome address within each group of 64
or 99 cameras is reserved as a global broadcast
address.
AD2050
Supported Protocol RS-422 (1)
Maximum Presets 16 (2) or 60 (3)
Maximum Patterns (4) 3
Quick Set Menu Not supported
Address Range 1-1024 (5)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored in
the dome, not the converter.
(4) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds. Total
dome commands used in all patterns cannot exceed
99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64
or 99 cameras is reserved as a global broadcast
address.