American Dynamics RAS917WLS Security Camera User Manual


 
Performance Notes
When selecting a dome, a 3- to 5-second delay is necessary for the Panasonic multiplexer to properly
identify the dome type. If the dome is moved before the interrogation is complete, the controller
recognizes the dome as a “single speed” dome. Once the dome stops moving and the interrogation
completes, the normal 8 speed settings are available.
Address Setting
The dome must have the correct address setting to operate with Panasonic UTC protocol. Set the
dome address switches to 890.
Programming Presets
You must use the Dome Configuration Menu to program Presets. Up to 64 Presets may be
programmed.
Note: This procedure has been verified using the following equipment:
WJ-SX550 Multiplexer
WV-CU550A Controller
1. Select the monitor and camera number assigned to the Speed Dome Ultra VII camera dome.
2. Use the arrow keys on the controller to scroll to the Camera Setup Menu (D4).
3. Press
F1 (On) key to display the Dome Configuration Menu.
4. Use the joystick to move the highlight to Alarms/Areas/Home/Presets/PZ. Press
Set to
select.
ALARMS/AREAS/HOME/PRESETS/PZ
SET ALARM ACTIONS
SET ALARM STATES
SET HOME POSITION
SET NORTH POSITION
AREA BOUNDARIES
PRIVACY ZONES
PRESETS
SCAN LIMITS
EXIT
D–4 SpeedDome Ultra VII Day/Night Operator's Manual