7
Defining the RFID Setup Packet for HF (9855 only)
Use the RFID setup packet (X) to set the protocol, write attempts and
attenuation.
Note: Refer to the HF Setup Guide and Supply Chart for the protocol and
attenuation settings based on your RFID supplies.
Syntax {I,X,protocol,write_attem,attenuation¦}
X1. X RFID Setup Packet
X2. protocol Select the HF protocol. The default is 0. Options:
0 AUTO-Select
1 TI ISO15693
2 NXP ISO15693
3 I-CODE UID
X3. write_attem The number of times the interrogator tries to program the
RFID tag in the RF Field. The range is 1 – 4. The
default is 3.
X4. attenuation The amount of power to read an RFID tag. The range is
1 – 4. The default is 2.
Example {I,X,0,3,2¦}
Uses the default protocol (AUTO-Select), sets the number of write attempts
to 3 and the attenuation to 2.
The test label has been updated to show the settings for the RFID Setup
Packet.