Axis Communications AXIS P3364-VE Security Camera User Manual


 
AXIS P3364-VE Network Camera
Technical Specifications
Digital input
3
Connect to pin 1 to activate, or leave oating (unconnected)
to deactivate
0 to max 40 V DC
Digital output
4
Connected to pin 1 when activated, oating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC, open drain,
100 mA
Connection Diagrams
I/O Connector
1
2
3
4
1
0 V DC (-)
2
DC output 3.3 V, max 50 mA
3
Digital input 0 to max 40 V DC
4
Digital output 0 to max 40 V DC, open drain, 100 mA
Audio Connector
3.5 mm audio connectors
(stereo)
123
1 Tip 2 Ring
3 Sleeve
Audio Input
Microphone/Line in
Ground
Audio Output
Line out (mono)
Ground
SD Card Slot
Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10.
64