Axis Communications network camera Security Camera User Manual


 
AXIS P3364-VE Network Camera
Technical Specications
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3.3 V DC
Max load = 50 mA
Digital Input
3
Connect to pin 1 to activate, or leave oating (unconnected)
to deactivate
0 to max 40 V DC
Digital Output
4
Connected to pin 1 when activated, oating (unconnected)
when deactivated. If used with an inductive load, e.g. a relay,
a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC, open drain,
100 mA
3.3 V max 50 mA
1
2
3
4
Audio Connector
3.5 mm audio connectors
(stereo)
123
Audio Input
Audio Output
1 Tip
Microphone/Line in
2 Ring
Line out (mono)
3 Sleeve Ground Ground
SD Card Slot
Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10.
Performance Considerations
When settings up your system, it is important to consider how various settings and situations will affect performance. Some factors
affect the amount of bandwidth (the bit rate) required, others can affect the frame rate, and some affect both. If the load on the
CPU reaches its maximum, this will also affect the frame rate.
61