Axis Communications P5415E Security Camera User Manual


 
AXIS P5415–E PTZ Dome Network Camera
Technical Specifications
Function/group
Item
Specications
Operating
conditions
Temperature: –20 °C to 50 °C (–4 °F to 122 °F)
Humidity 10–100% RH (condensing)
Approvals
EN 50121–4, IEC 62236–4, EN 55022 Class B, EN 61000-6-1, EN 61000-6-2,
EN 55024, FCC Part 15 Subpart B Class B, ICES-003 Class B, VCCI Class B,
C-tick AS/NZS CISPR 22 Class B, KCC KN22 Class B, KN24, IEC/EN/UL 60950-1,
IEC/EN/UL 60950-22, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-6, IEC 60068-2-14,
IEC 60068-2-27, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 IP66, EN 50581,
NEMA 250 Type 4X, ISO 4892-2
Weight
3.5 kg (7.7 lb)
Included
accessories
Installation Guide, AVHS Authentication key, installation and management software CD,
Windows decoder 1–user license
Video
management
software (sold
separately)
AXIS Camera Companion (included), AXIS Camera Station and video management
software from Axis’ Application Development Partners (not included). For more
information, see www.axis.com/products/video/software
Optional
accessories
AXIS P54 Smoked dome
T8123 High PoE-30W Midspan 1-port
AXIS T94P01B Corner Bracket
AXIS T8310 Video Surveillance Control Board
AXIS T90A Illuminators
AXIS High PoE midspans
Installation Display
Multi-user decoder license pack
Connectors
I/O Terminal Connector
6–pin terminal block for:
Digital Input
Digital Output
0 V DC (-)
1 2 3 4 5 6
Function Pin Notes
Specications
0 V DC (-)
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC Power
Max load = 50 mA
Digital input – Connect to pin 1 to activate, or leave oating
(unconnected) to deactivate.
0 to +30 V DCCongurable
(Input or Output)
3–6
Digital output – Connected to pin 1 when activated, oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Max load = 100 mA
Max voltage = +30 V DC
65