IP Camera 200 Series Advanced Mode | en 81
Bosch Security Systems Installation and Operation Manual AR18-10-B012 | v1.5 | 2011.01
Relay follows
If required, select a specific event that will trigger the relay. The
following events are possible triggers:
– Off: Relay is not triggered by events
– Connection: Trigger whenever a connection is made
– Video alarm %sTrigger by interruption of the video signal
– Motion alarm %sTrigger by motion alarm, as configured on
the VCA page
– Local input %sTrigger by the corresponding external alarm
input
– Remote input %s: Trigger by remote station's
corresponding switching contact (only if a connection
exists)
Relay name
The relay can be assigned a name here. The name is shown on
the button next to Trigger relay. The LIVEPAGE can also be
configured to display the name next to the relay icon. (Do not
use any special characters, for example &.)
Trigger relay
Click the button to switch the relay manually (for example, for
testing purposes or to operate a door opener).