EverFocus EZ180 Film Camera User Manual


 
1. Using the supplied screws, mount the bracket base on the desired
location.
2. Connect the BNC connector of the camera to a monitor or other
video device through a 75 ohm type coaxial cable with BNC female
connector at cable extension.
3. Connect the 24VAC or 12VDC regulated power source of the camera
(power jack) to the power-in jack with 2mm plug. For 12VDC
power source, please make sure the power plug is center+ outer-
for heater normal operation.
4. Our factory settings is for you to get the best image within about 3~5
meters (for veri-focal lens f=3.5~8mm) or 5~10 meters (for
veri-focal lens f=9~22mm) . If it is out of focus, or any other
adjustment is required, follow the procedures below.
a. Remove the fixing screw in the front, which hold the sun shield
cover. Remove the sun shield cover.
b. Twist open and carefully remove the housing cover.
(Please pay attention to prevent damage to the “O”-Ring seal.)
c. Loosen the focal lens and focus locking screws.
d. Adjust the lens to bring the subject into focus.
(
Caution: Heater elements could be hot! When camera power is
on, use caution when adjusting the camera.)
e. Retighten the screws.
f. Please refer to the Settings section for the details of the other
adjustments. Adjust accordingly if necessary.
Installation Instructions
5