Fujitsu M3097E Photo Scanner User Manual


 
Subwindow control register #10
7
0
6
0
5
0
4
0
3
0
2 1 0
LSB
000: Light Darken more
001 and more
010: Somewhat light
011
100: Normal
101
110: Somewhat dark
111: Dark
Density (*1)
*1 Valid if bit 0 of subwindow control register #16 is 0 (eight>step selection).
Otherwise, the density specification in subwindow control register #17 is valid
(256>step selection).
X©04π is set when the power is turned on or when the initial state is specified by the
CLEAR command.