Fujitsu M3097E Photo Scanner User Manual


 
Subwindow control register #12
#12
7
0
6
0
5
0
4 3
0
2
0
1 0
0
LSB
Automatic separation specification (*2)
0: Not specified
1: Specified
Black/white conversion mode
specification
0: Normal
1: Reverse
(*1)
*1 Subwindow control registers #12 to #14 must be sent in one sequence.
One of automatic separation, image emphasis, outline extract, overlay can be
specified.
*2 When image area separation is specified, the density level for line drawing area
follows the subwindow control register #10 or #17, and the dither pattern for
photo area follows the subwindow control register #11, and halftone processing
for photo area follows subwindow control register #16.
X©00π is set when the power is turned on or when the initial state is specified by the
CLEAR command.
50FH5037E>02 6 $ 39