1-20 SPARC Enterprise M4000/M5000 Servers Overview Guide • August 2009
1.3.6 Operator Panel
The operator panel (FIGURE 1-15), which is not redundant, displays the system status,
system problem alerts, and location of system faults. It also stores the system
identification and user setting information. For more information on the operator
panel functions, refer to the SPARC Enterprise M4000/M5000 Servers Service Manual.
TABLE 1-7 Power Consumption Example for an M4000 System
*
* M4000 system configuration: CPUM x 2, MEMB x 4, 4GB DIMM x 32, HDD x 2, PCIe x 4, PCI-X x 1, DAT x 1.
CPU type Frequency (GHz) Number Power Consumption (W) Apparent Power (VA) Heat Dissipation (KJ/h)
SPARC 64 VI
processor
2.15 4 1556 1620 5600
SPARC 64 VII
processor
2.4
2.53
4
4
1656
1656
1725
1725
5960
5960
TABLE 1-8 Power Consumption Example for an M5000 System
*
* M5000 system configuration: CPUM x 4, MEMB x 8, 4GB DIMM x 64, HDD x 4, PCIe x 8, PCI-X x 2, DAT x 1.
CPU type Frequency (GHz) Number Power Consumption (W) Apparent Power (VA)
Heat Dissipation
(KJ/h)
SPARC 64 VI
processor
2.15 8 2998 3123 10791
SPARC 64 VII
processor
2.4
2.53
8
8
3198
3198
3331
3331
11511
11511