Hitachi BE-IR20 Digital Camera User Manual


 
11. Function setting and changes
BE-IR20 / 21
16
11-6 BE-IR21 internal sync
The BE-IR21 factory setting is for external sync. If required, this can be changed to internal
sync by changing chip parts.
Change the following chip parts for internal sync operation.
Sync system R280 R281 R282 R284
External Absent 0 100 Absent Factory setting
Internal 100 Delete Delete 0
0
Part code RME1784
Type ERJ3GEYJ0R00V
100
Part code RME1797
Type ERJ3GEYJ101V
(Main board side A) (Main board side B)
Location of chip resistors