KP-FD30 remote control command table (Rev.1)
1) Standard command
a) Write command (Set data)
TEXT data Item STX
Status ID Area R.No Data
ETX SUM
AVE
(*)
02 01 FF 01 3A 00 00 00 03 18
AREA 02 01 FF 01 3A 01 00 00 03 17
Auto Light Control Mode (ALC)
PEAK/AVE 02 01 FF 01 3A 00 00 00 03 16
NO.1
(*)
02 01 FF 01 1C 00 00 00 03 18
NO.2 02 01 FF 01 1C 01 00 00 03 17
NO.3 02 01 FF 01 1C 02 00 00 03 16
NO.4 02 01 FF 01 1C 03 00 00 03 15
NO.5 02 01 FF 01 1C 04 00 00 03 14
NO.6 02 01 FF 01 1C 05 00 00 03 13
NO.7 02 01 FF 01 1C 06 00 00 03 12
NO.8 02 01 FF 01 1C 07 00 00 03 11
Area of Light measurement
AREA SELECT (ALC: AREA)
Image
NO.9 02 01 FF 01 1C 08 00 00 03 10
0/100
(*)
02 01 FF 01 39 00 00 00 03 20
15/ 85 02 01 FF 01 39 01 00 00 03 1F
30/ 70 02 01 FF 01 39 02 00 00 03 1E
50/ 50 02 01 FF 01 39 03 00 00 03 1D
75/ 25 02 01 FF 01 39 04 00 00 03 1C
Ratio of Peak & Average
(ALC :PK/AV)
100/ 0 02 01 FF 01 39 05 00 00 03 1B
Min 02 01 FF 01 0C 00 00 00 03 19
| 02 01 FF 01 0C ** 00 00 03 **
Mid
(*)
02 01 FF 01 0C 80 00 00 03 11
| 02 01 FF 01 0C ** 00 00 03 **
Video Level (ALC: LEVEL)
[ 00–FF ]
Max 02 01 FF 01 0C FF 00 00 03 ED
OFF
(*)
02 01 FF 01 06 00 00 00 03 26
Auto Gain Control Mode (AGC)
ON 02 01 FF 01 06 01 00 00 03 25
Min
(*)
02 01 FF 01 2D 00 00 00 03 16
| 02 01 FF 01 2D ** 00 00 03 **
FIX. GAIN (AGC: OFF) [00-FF]
FIX. GAIN(dB) = 0.132 x DATA
Max 02 01 FF 01 2D 88 00 00 03 06
Min 02 01 FF 01 2F 00 00 00 03 14
| 02 01 FF 01 2F ** 00 00 03 **
AGC LIMIT (AGC: ON) [00-FF]
AGC LIMIT(dB) = 0.132x DATA
Max
(*)
02 01 FF 01 2F 88 00 00 03 04
(*)
: Factory setting