2) Special command (For adjustment of a factory)
Caution !!
The item indicated by the special command is adjusted to the optimal value at the time of factory
shipments. Please perform after reading the data set up now by the lead command and
memorizing a setting value, when changing this item.
The table shown below is written by the command (Status: 00) which does not memorize a setting
value to EEPROM inside a camera. When you memorize a setting value, please set status to “01”
and transmit.
a) Write command (Set data)
TEXT data Item STX
Status ID Area R.No Data
ETX SUM
Min 02 00 FF 01 2E 00 00 00 03 16
| 02 00 FF 01 2E ** 00 00 03 **
Standard sensitivity adjustment
(Standard Gain) [00-77]
Max 02 00 FF 01 2E 77 00 00 03 08
Min 02 00 FF 01 19 00 00 00 03 23
| 02 00 FF 01 19 ** 00 00 03 **
ALC Level Ref. [00-FF]
Max 02 00 FF 01 19 FF 00 00 03 F7
Min 02 00 FF 01 3F 00 00 00 03 14
| 02 00 FF 01 3F ** 00 00 03 **
Peak data Ref. [00-FF]
Max 02 00 FF 01 3F FF 00 00 03 E8
Min 02 00 FF 01 0A 00 00 00 03 1C
| 02 00 FF 01 0A ** 00 00 03 **
Auto Iris Ref. [00-FF]
Max 02 00 FF 01 0A FF 00 00 03 F0
Min 02 00 FF 02 81 00 00 00 03 23
| 02 00 FF 02 81 ** ** 00 03 **
White Balance- R gain Ref.
[0000-07FF]
Max 02 00 FF 02 81 FF 07 00 03 F0
Min 02 00 FF 02 84 00 00 00 03 20
| 02 00 FF 02 84 ** ** 00 03 **
White Balance- B gain Ref.
[0000-07FF]
Max 02 00 FF 02 84 FF 07 00 03 ED
Min 02 00 FF 02 9B 00 00 00 03 11
| 02 00 FF 02 9B ** ** 00 03 **
C-Y Matrix (Gr-y,r-g)
[0000-01FF]
Max 02 00 FF 02 9B FF 01 00 03 E4
Min 02 00 FF 02 9C 00 00 00 03 10
| 02 00 FF 02 9C ** ** 00 03 **
C-Y Matrix (Gb-y,b-g)
[0000-01FF]
Max 02 00 FF 02 9C FF 01 00 03 E3