Honeywell HCD484L Digital Camera User Manual


 
Rev 2 7 G-113079-002
02/07
3. Plug in the power supply. The power (PWR) LED
illuminates to show that the camera is receiving power.
If it does not illuminate, check the connections and the
power source.
Figure 6 Camera Connections
Remote Control Connections
The L-Series Day/Night Color camera can be controlled
remotely using an RS485 connection.
Figure 7 RS485 Camera Connection
PWR
VSD
DC
VIDEO
~207-253VAC 50HZ
REMOT E
UP
DOWN
MENU
+
Connect to
Monitor
Power LED
Mains (230V) version shown
(HCD485L)
-+
GND
DC 12V
AC 24V
PWR
VSD
DC
VIDEO
+
UP
DOWN
MENU
REMOTE
RS485 Converter
TRx+
TRx-
4P Cable
3 TRx+
2 TRx-
4P CableConnect to
Serial Port
(COM1 or
COM2)
Serial
cable
4-Pin Cable Legend
1. Red Not used
2. Blue TRx-
3. Yellow TRx+
4. Black Not used
RS485