Honeywell HD3MDIHX Security Camera User Manual


 
HD3MDIH/X EQUIP Series Indoor High Resolution True Day/Night IP Dome Camera User Guide
Document 800-07361 Rev A 27
12/10
Adjusting the Lens Focus
Lenses are pre-focused at the factory. They might require a final adjustment after
installation because the optical effect of the dome bubble might cause a slight defocusing
of the lens.
TECH TIP! To check the focus, hold the dome bubble over the lens while making any adjustments.
To adjust the camera direction, view angle, and focus, connect the local video out to the
video monitor using the supplied BNC video cable.
Securing the Enclosure Cover
Install the dome bubble when you have set up your camera and completed the network
connections (see Chapter 3, Installing the Honeywell IP Utility and Web-Client Software).
Place the enclosure cover on the camera with the tabs to the left of the slots, then turn it
clockwise until the tabs click securely into place.
Figure 2-9 Installing the Enclosure Cover