ICP DAS USA IM-100 Camcorder User Manual


 
IMC_OutputPort_Configure
Syntax:
Visual C++ 6.0 / Boland C++ Builder 6.0:
short IMC_OutputPort_Configure ( HANDLE Camera_Handle, int Output_Port, int
Source_Signal);
Visual Basic 6.0
IMC_OutputPort_Configure (ByVal Camera_Handle As Long, ByVal Output_Port As
Long, ByVal Source_Signal As Long) As Integer
C#.NET 2003
Mavis.IMC_OutputPort_Configure( IntPtr Camera_Handle, int Output_Port, int
Source_Signal );
Description:
This function configures the hardware sources for specific Output Port. The camera
needs be initialized with IMC_Camera_Init().
Parameters:
Camera_Handle The handle for MAVIS camera, use the handle gotten from the
pHandle’ parameter of IMC_Camera_Init().
Output_Port: The Output Port to be configured. The Ports can
be:
OUTPUT_PORT_0, OUTPUT_PORT_1,
OUTPUT_PORT_2 and OUTPUT_PORT_3
Signal_Source The hardware Signal Source for Output Port and the sources
can be:
INTEGRATE_ENABLED_SIGNAL (0x00),
TRIGGER_READY_SIGNAL (0x01),
USER_SET_SIGNAL (0x03)
STROBE_SIGNAL (0x04)
- 77 -