JVC VN-685U Security Camera User Manual


 
29
3 Connecting the alarm cable (A
Page 25)
Connect the alarm cable and wind the
waterproof tape (adhesive).
After connecting, push the cable into the arm of
the camera.
Note:
For cables that are not used, be sure to wrap
the ends individually with insulating tape.
For safety reasons, turn on the power only
after all the connection is complete.
4 Mount the cap
5 Seal the cable connection hole and
around the mounting surface of the
camera with waterproof seal (GE
silicon).
Note:
Ensure that waterproof treatment is
performed. Otherwise, the camera may
malfunction due to rain water seepage.
Use GE silicon or other similar product for the
sealing material.
6 Remove the dome cover protective
sheet
Wind the waterproof tape
(adhesive)
Arm
4
5
Waterproof
treatment
Cap
Protective
sheet