JVC VN-C3WU Security Camera User Manual


 
13
2. Connecting to a network
Turn on the power of only one VN-C3WU unit.
When network connection is completed and the power is turned on, the
VN-C3WU unit will be connected to the network at the following IP ad-
dress.
Factory set (Default) IP address 192. 168. 0. 2
About the power supply connection cable
Length: 30m or less.
Recommended model: UL1007, UL1015 or equivalent cable with wire
equivalent to ID AWG #20 or larger.
Caution
All VN-C3WU units are set to the same IP address at the factory; therefore,
if the power of multiple VN-C3WU units is turned on at the same time,
address duplication will occur and correct access will not be possible. Always
turn the power on for only one unit at a time. If address duplication occurred,
perform the proper processing and wait for 10 min. or more, or turn off the
power of all units on the network and then turn the power on again;
otherwise, correct access may not be possible.
Use a straight cable when
connecting to a hub.
Use a cross cable when
connecting directly to a PC.
Power supply connection cable
Caution
VN-C3WU unit is intended to be Supplied by a Listed Direct Plug-In Power
Unit marked “Class 2” and rated from 11 to 15 V dc, 2 to 2.5 A.
VM-C3WU_E.65J 00.10.12, 7:13 PMPage 13 Adobe PageMaker 6.5J/PPC