4
LST1238-001B
Specifications
External dimensions (unit: mm)
*
The specifications and appearance of this unit are subject to change for purposes of improvement without prior notice.
Camera
section
Image sensor
1/3-inch Square-Pixel Progressive Scan CMOS (elementary color filter)
Effective pixels
Approximately 2,120,000 pixels
1944 (H) × 1092 (V)
Minimum illuminance
of subject
(50%, AGC High, 1/30 s)
Color: 0.3 lx (typ.)
Black and White 0.03 lx (typ.)
Monitor output
75 Ω, 1.0 Vp-p
NTSC or PAL (switch selectable)
Audio input
Input Can connect to a microphone that has a plug-in power system
Reference voltage DC2.47 V(typ.)
Impedance 2.2 kΩ (typ.)
Audio output Line OUT (200 Ω, Max 1.9 Vp-p)
Network
output
Image compression
format
JPEG, H.264 High Profile, H.264 Baseline Profile, MPEG-4
Frame size
1920 x 1080
1280 x 960
1280 x 720
640 x 480
640 x 360
320 x 240
Audio compression
formats
μ-Law(64 kbps), AD/DA 16bits, Fs = 8 kHz, monaural
Network interface
RJ-45
100BASE-TX/10BASE-T/FULL/HALF/Auto-negotiation enabled
Alarm input
No-voltage a contact input, PNP open collector input, low level,
latch/momentary (500 msec or longer) (1 mA circuit current at low
level, and 3.3 VDC applied voltage at high level)
Alarm output
NPN open collector-output (16 VDC safe excitation voltage, and
30 mA allowable sink current)
Alarm record 16 MB
Lens
Focal length f = 3 mm to 9 mm
Maximum aperture
ratio
F 1.2 (f =3 mm) to F 2.1 (f =9 mm)
Aperture range F 1.2 to F 360
Zoom ratio 3 x
LAN
standards
Standards
Compliant with IEEE802.3, IEEE802.3u and IEEE802.3af
Communication
protocol
TCP/IP, UDP/IP, FTP, ICMP, ARP, DHCP, SNTP, HTTP, SMTP, RTP,
RTSP, IPv4, IPv6, DSCP, HTTPS, SNMP
General
Power supply voltage AC24 V 50 Hz/60 Hz, or PoE(DC-48 V)
Current consumption
AC24 V 0.5 A, or PoE 150 mA (7.2 W)
Ambient temperature
-10 °C to 50 °C (Operation)
0 °C to 40 °C (Recommended)
Ambient humidity 20 %RH to 90 %RH (without condensation)
Mass Approx. 1.8 kg
Dustproof/Waterproof
IP66 compliant
Audio cable connection
Cables
Alarm cable connection
Alarm input
Connect an infrared sensor, door sensor, metal
sensor, a manual switch or other device.
To avoid noise entering the internal circuit, enter the
non-voltage contact signal in the Alarm IN terminal.
Do not supply voltage.
The alarm can be set to be activated during close
contact (MAKE) or during open contact (BREAK)
can be set from the menu.
The alarm signal should last for at least 500
msec. If the alarm signal is short, it may not be
recognized.
Input conditions
Connect non-voltage a contact or NPN open
collector output circuit
(For details on how to set polarities, please refer to
“Instructions (Setting)”.)
Low level terminal current below 1 mA
High level terminal current 3.3 V
3.3 V 1 mA
VCC
OUT
G
G
OUT
R
G
DC3.3 V
This
camera
Input 1 or
Input 2
(Alarm input equivalent circuit)
Sensor example (1)
Sensor example (2)
Relay switch or
other devices
•
•
•
•
●
•
•
•
Alarm output
Connect an alarm device, indicator, lighting, buzzer or
other device.
An alarm output signal is an open collector output.
You can configure the menu to set the alarm to
sound when contacts short circuit (MAKE) or
when the contacts are open (BREAK). (Pressure
resistance lower than 16V, 30 mA)
This terminal has different polarities. The output
voltage at the positive terminal must always be
higher than the output voltage at the negative
terminal. Otherwise, the circuit may be damaged.
Output conditions
Equivalent to NPN open collector output
(For details on how to set the output logic, please
refer to “Instructions (Setting)”.)
Safe excitation voltage: DC12 V or lower
Allowable surge current: 50 mA
Momentary (100 ms to 5000 ms) output
(For details on how to set the time, please refer to
“Instructions (Setting)”.)
IN
R
DC12 V
G
G
This
camera
Output 1 or
Output 2
(Alarm output equivalent circuit)
Alarm device
example
Note
Connect the G terminal cable of this camera to the
GND of the alarm device.
•
•
●
•
•
•
•
•
1
2
3
Cable type Color Signal name
1 Power cable
Red AC 24 V
Black AC 24 V
2 Audio/Alarm cable
Alarm
Brown INPUT 1 (ALARM)
Red INPUT 2 (ALARM)
Orange OUTPUT 1 (ALARM)
Yellow OUTPUT 2 (ALARM)
Black GND (ALARM)
Audio
White MIC IN
Black GND (MIC IN)
Light Green LINE OUT
Black GND (LINE OUT)
3 LAN cable
Black
(Shielded cable)
RJ-45
10BASE-T/
100BASE-TX
Connecting the power cable to AC 24 V source
Conductor
diameter (mm)
1.0 mm dia
or more
1.6 mm dia
or more
2.0 mm dia
or more
Max cable
distance (meters)
(Reference value)
90 240 370
Note
For safety reasons, turn on the power only after
confirming that all the connections are completed.
Be sure to turn off the camera before connecting cables.
If you use both the AC 24 V power cable and the
PoE-based LAN cable simultaneously, the camera
may fail. Always supply power using either method.
To use an AC 24 V power supply, remove the
factory-installed tape from the power cable, connect
to an AC 24 V power supply, and wrap the connector
with new insulation tape and waterproof tape.
●
•
•
•
•
LAN cable
When connecting to a switching hub:
Use a straight cable.
When connecting to a computer:
Use a crossing cable.
A 100-meter or less length and Category-5 or higher
grade STP (shielded) cable is recommended.
Note
The crossing cable may not be used for some
computer models. Check the LAN specifications of
the computer when you directly connect this unit to
the computer.
Alarm cable
A 50-meter or less length shielded cable is
recommended.
●
•
•
•
•
●
•
Connect the audio cable for an audio device.
Audio cable (White and Black) (MIC IN) : Connect to a condenser microphone that has a plug-in
power system, etc.
Audio cable (Light Green and Black) (LINE OUT) : Connect to a speaker with a built-in amp, etc.
Memo
A shielded audio cable is recommended.•
Ø140 184.5
257.5
214.5
165.5
Ø50
Troubleshooting
Symptom Causes and Countermeasures
Movement of network image is not
smooth
If the monitor image output is turned ON, a lower frame rate is set for
network images.
If you turned the monitor image output to OFF, set the frame rate
again.(
☞ “Instructions (Setting)” - “Internet Explorer Setting” -
“Encoding Page”)
•
•
No monitor image is output. The image output may be turned Off on Internet Explorer.
Check the monitor output setting.
The external mic sound is not
heard.
Check the MIC connection.
Is the audio setting turned off? (
☞ “Instructions (Setting)” - “Audio
Page”)
•
•
Lens is out of focus Is the focus adjustment gear engaged? Check the location of the catch.
(Maximum shade extention)
EN_VN-H157WVP_001B_Non-Mask.indb4 4EN_VN-H157WVP_001B_Non-Mask.indb4 4 5/25/2012 11:59:04 AM5/25/2012 11:59:04 AM