Kodak 7231TM Film Camera User Manual


 
EASTMAN PLUS-X Negative Film 5231™ / 7231™ H-1-5231 3
Sensitometric Curves
Modulation-Transfer Curve
=0.63
=0.70
=0.76
4 min
5 min
6 min
=0.19Base Density
intensity-scale sensitometer
D-96 at 21 C (70 F)
KODAK Developer
Status M (Blue)
Processing:
Exposure:
Densitometry:
Daylight, 1/50 sec,
6
Fog
5
0.8
4
0.6
0.7
GAMMA
DEVELOPMENT TIME
Gamma
(minutes)
0.00
0.02
FOG
NET
LOG EXPOSURE (lux-seconds)
2.03.0
0.0
DENSITY
1.0
2.0
3.0
1.01.0 0.0
F002_0142AC
C a ac e s c Cu es
200
50
70
100
20
30
7
3
5
2
1
10
RESPONSE (%)
SPATIAL FREQUENCY (cycles/mm)
60020050201054321 100
Modulation Transfer
Curve
F002_0141AC
Spectral-Sensitivity Curves
Notice: While the data presented are typical of production
coatings, they do not represent standards which must be met
by Kodak. Varying storage, exposure, and processing
conditions will affect results. The company reserves the right
to change and improve product character- istics at any time.
These photographic modulation-transfer values were
determined by using a method similar to the one described in
ANSI Standard PH2.39-1977(R1990). The film was
exposed with the specified illuminant to spatially varying
sinusoidal test patterns having an aerial image modulation of
a nominal 60 percent at the image plane, with processing as
indicated. In most cases, these photographic
modulation-transfer values are influenced by
development-adjacency effects and are not equivalent to the
true optical modulation-transfer curve of the emulsion layer
in the particular photographic product.
y
F002_0143AC
3.0
2.0
1.0
*
1.0
0.0
LOG SENSITIVITY
2
WAVELENGTH (nm)
to produce specified density
*Sensitivity = reciprocal of exposure (ergs/cm ) required
250 300 350 400 450 500 550 600 650 750700
1.4 seconds
Densitometry:
Effective Exposure:
Process:KODAK Developer D-96
Diffuse visual
at 21 C (70 F) to the
recommended control gamma
D=0.3 Above gross fog