Continuous Use
Do not use the flash continuously for more than the number of times stipulated
in the table below, in order to prevent damage to the unit. Once the maximum
number of flashes has been reached, allow the flash to rest for at least 10 minutes
before using it again.
Mode
Maximum Use
3DMULT, TTL, M(1/1 1/2)
15
M (1/4 1/16)
20
10
Technical Specifications of PZ40X
Guide Number : ISO 100 (m/ft)
English
24mm
(0.9in)
24/78 26/85 28/92 34/111 40/131
Zoom setting
Manual flash
1/1
1/2
1/4
1/8
1/16
Working Range ( m/ft )
Zoom position
24mm(0.9in) 28mm(1.1in) 35mm(1.4in) 50mm(2.0in) 80mm(3.1in)
F/2
F/4
F/8
F/16
12/40 14/46
6/20 7/23
3/10 3.5/11
1.5/5 1.8/6
17.5/57
8.8/29
4.4/14
2.2/7
25/82
12.5/41
6.3/21
3.1/10
40/130
20/66
10/33
5/16
Numbers of flashes and Recycling time
Number of flashes Recycling time
AA Ni-MH Batteries
AA alkaline batteries
Approx 140 Approx 8 sec
Approx 100 Approx 10 sec
* Numbers of flashes: Measured with new batteries that are within 3 months from their date of
production, flashed every 30 seconds continuously and recycled to the point at which the Ready Light
takes 30 seconds to come on after the last flash.
Recycling time: The time to activate the Ready Light under the above conditions.
Power Zoom Automatic setting / Signal from camera
Manual setting / Pressing the Zoom Button
AF illuminator Range 1-5m (22 – 16in) (Lens F2/50mm)
Operating temperature 0 40
Dimensions 93(H)X63(W)X90(L)mm (3.6 x 2.4 x 3.5 in)
Weight 200g (7.0 oz)
Note. The design and specifications of this product are subject to change without prior notice.
28mm
(1.1in)
35mm
(1.4in)
50mm
(2.0in)
80mm
(3.1in)
17/56 18/59 20/66 24/78 28/92
12/40 13/43 14/46 17/56 20/66
8/26 9/30 10/33 12/40 14/46
6/20 6/20 7/23 8/26 10/33