27
Item setting operations (settings)
The current settings are displayed on the setting screen
When you change a setting and then select the “SET” button on the
screen, the new value is reflected on the unit
When a setting has also been changed on the unit, the value that
was set last takes priority
In a case like this, there may be a discrepancy in the values set
When a setting outside the setting range is selected using
keyboard input and the “SET” button is selected, the input check
will result in an error
In a case like this, the setting item will be restored to its original
value
Notes
Description of menus
Initial screen
This is the screen that appears first when a connection is established to
the URL you specified on the computer
The menu for the “SETTING1” item on the “OPERATION” menu is
displayed
Items when the OPERATION menu is
selected
Display the SETTING1 screen
Display the SETTING2 screen
Display the HD/SD PHASE screen
Display the BAR ID screen
Display the INCOM/MIC screen
SETTING1 Screen
indicates the factory default setting
Item
Setting
value
Remarks
CCU MODE
5994 Hz:
1080/5994i
1080/50i
Set the format of the signal to be output
from the unit
50 Hz:
1080/5994i
1080/50i
SDI RETURN 1
HD
SD
Set the format of the return signal to be
input to [HD/SD SDI 1] of the RETURN
IN connectors
SDI RETURN 2
HD
SD
Set the format of the return signal to be
input to [HD/SD SDI 2] of the RETURN
IN connectors
SDI OUTPUT 1&2
HD
SD
Set the format of the signals to be
output from [1] and [2] of the HD/SD
SDI OUT connectors
SDI OUTPUT 3&4
HD
SD
Set the format of the signals to be
output from [3/PM] and [4/PM] of the
HD/SD SDI OUT connectors
SDI OUTPUT 3&4
(NORMAL/PM)
NORMAL
PM
Set the signal to be output from [3/PM]
and [4/PM] of the HD/SD SDI OUT
connectors
NORMAL:
Output the main line images
PM:
Output the picture monitor images
COMPOSITE
(NORMAL/PM)
NORMAL
PM
Set the signal to be output from
[OUT/PM] of the VBS connectors
NORMAL:
Output the main line images
PM:
Output the picture monitor images
When the SDI OUTPUT3&4 (NORMAL/PM) item and COMPOSITE
(NORMAL/PM) item are set to “NORMAL”, the menus and statuses
will not be able to be displayed because the picture monitor images
will not be output
When you set one of items to “NORMAL”, set the other one to “PM”
When you set both of the items to “NORMAL”, priority is given to
the setting of the SDI OUTPUT3&4 (NORMAL/PM) item and the
COMPOSITE (NORMAL/PM) item is set to “PM”
Web settings (Continued)