M6
18
Item
Required when installing the mounting
bracket over the wall with the unicorn
anchor
Coaxial cable UL Listed NEC type CM or
CL2, RG-6/U type
Recommended distance: 20 m
{65.6 ft.} or less
Use
For connection between an external
video-input device and the iris reader
Connect both ends with BNC plugs.
Power cable
Item number/Recommended type
UL style 1015 (AWG 14-18) or
equivalents
Maximum distance:
10 m {32.8 ft.}
Necessary when supplying power from
the external power-supply device to
the iris reader
Solder both ends of the cable with M3
screw clamp terminals.
LAN cable UL style 1666, CSA-FT4 or equivalents
10 Base-T/100 Base-TX (Category 5)
*1
Necessary for communication between
the iris readers and iris server
Anchor bolt
■ Preparation
Prepare the following items before the installation. The necessary items and their lengths differ depending on situation.
● Preparing the Necessary Items
*
1
Only cables without connector covers are usable.
Notes:
•When you use the alarm output and Wiegand terminals, you need optional cables suited for the connectors of external
devices. Use the UL style 1571 or equivalents, AWG 22 - 16 wire.
•When you use the RS-485 terminals, you need optional twisted pair cables (AWG 22 - 16) suited for the connectors of
external devices.
• It is recommended to use shielded twisted pair cables for the open collector output connectors (
!6 - !9). (GND @0 is to be
paired.)*
2
*
2
!6, !9, and @0 are Pin No. Refer to p.16.
● Cable Preparation
Power cable (with sealing)
■ Notification about the Installation Site
This iris reader is limited to indoor use.
Near-infrared light (contained in sunlight, incandescent light and halogen light) are used for iris image capturing by the iris
reader. If the iris reader is installed in a place which receives this light directly, it may cause invalid iris data
enrollment/recognition, as the iris reader cannot capture iris images properly.
Keep the iris reader away from the following. Otherwise, light may affect on the iris reader.
• Outdoor places
•Direct sunlight or light reflection
•Incandescent or halogen lighting
•Places where the iris reader or the user's eyes are directly exposed to light
25 mm {1 in.} or less