-31-
6-1. Internal Sync Mode (INT)
1. Move the cursor to SYNC and select INT.
2. Press I.
Note: Never supply VD2, VBS, or VS to the camera
when you intend to operate the camera in the
internal mode. Otherwise your selection will be
ignored because INT has the lowest priority.
6-2. VBS Gen-lock Mode (EXT(VBS))
1. Move the cursor to the SYNC parameter and select
INT.
2. Connect the coaxial cable for the blackburst or
composite color video signal to the gen-lock input
connector.
3. Confirm that the INT parameter changed to EXT
(VBS) on the menu.
Caution: The gen-lock input signal should meet the
EIA specifications and should not contain jitter,
such as a VCR playback signal, as it could dis-
turb synchronization.
4. After confirming that the cursor is on EXT (VBS),
press I. The phase adjustment menu appears
on the monitor.
5. Supply the video output signal of the camera to be
adjusted and the reference gen-lock input signal to
a dual-trace oscilloscope.
SC FINE ....I....